Search
Close this search box.
The Darko logo showcases a bold design, representing quality and innovation.
Search

CONATCT

MORE+

Cyclone dust collectors  (also referred to as a cyclone separator or simply a cyclone) are essential in various industrial applications for controlling air quality and minimizing dust emissions. The efficiency of these cyclonic systems hinges on the precise dimensions and relationships of their components.

In this blog, we’ll explore the critical factors that influence the performance of cyclone dust collectors, along with best practices for installation and usage.

The Cyclone Dust Collector is positioned outdoors, effectively separating dust from the air in the industrial setting.

WHAT ARE THE ADVANTAGES AND DISADVANTAGES OF CYCLONE DUST COLLECTORS? 

Advantages

1. Dry Cleaning Method: The dry cleaning method facilitates the centralized treatment and recycling of dust.

2. Corrosive Dust Handling: Cyclone can be used to treat corrosive dust gas.

3. Compact Design: The cyclone separator is small and occupies less space, therefore making it easy to install. Additionally, it has a simple structure and is relatively inexpensive.

4. User-Friendly: The cyclone structure is not complex, making it easy to use.

5. High-Temperature Gas Purification: Cyclone can purify high-temperature dusty gases. The cyclone dust collector made of carbon steel can handle gas temperatures up to 100°C, while those with refractory materials can process gases at 500°C.

Disadvantages

1. Limited Handling Capacity: Due to the small handling capacity of a single cyclone dust collection unit, multiple cyclone collection units need to be connected in parallel for larger volumes.

2. Ineffective on Fine Dust: A cyclone separator is not suitable for treating dust particles smaller than 5μm. For light dust particles and high filtration efficiency, baghouse filters are the preferred choice.

3. Not Suitable for Sticky Dust:The cyclones are ineffective in purifying sticky dust particles.

WHAT ARE THE FACTORS AFFECTING THE EFFICIENCY OF A CYCLONE?

1. Inlet Size

The inlet is a crucial component of a cyclone dust collector, significantly impacting dust removal efficiency. A smaller inlet area increases airflow velocity, which enhances dust separation from other particles.

 

2. Diameter and Height of the Cyclone Cylinder

 

The diameter and height of the cylindrical body influence the efficiency of the cyclone.With a constant rotational airflow speed, a larger diameter results in reduced centrifugal force on the dust particles. This leads to lower dust removal efficiency and makes it harder for dust to be drawn into the machine. Therefore, the inlet diameter should not be excessively large or too small. A suitable size is essential to avoid clogging by larger dust particles.

 

3.Diameter and Depth of the Exhaust Pipe

 

The diameter and depth of the exhaust pipe also affect cyclone dust removal efficiency. A smaller diameter in the exhaust pipe restricts airflow, making it more difficult for dust to exit. To improve efficiency, it’s important to increase the exhaust velocity and the pipe diameter.

HOW DO YOU CHOOSE A CYCLONE SEPARATOR?

1.Matching Purification Capacity

The actual amount of dust-laden gas to be processed should match the capacity of the cyclone dust collector. Therefore, when you select the diameter of the cyclone dust collector, keep it as small as possible. If you require a larger airflow, then you can use several smaller diameter cyclone dust collectors in parallel.

2.Inlet Airspeed

The inlet airflow velocity should be maintained between 18 and 23 m/s. If the velocity is too low, dust removal efficiency will decrease. On the other hand, if the velocity is too high, resistance loss will increase. And power consumption will also rise, resulting in little improvement in dust removal efficiency.

3. Low Resistance Loss

You should select a cyclone dust collector with low resistance loss. Additionally, it should have low power consumption. Finally, it should feature a simple structure for easy maintenance.

4. Minimum Dust Particle Capture

The cyclone dust collector should capture the smallest dust particle size. This size should be slightly smaller than the particle size in the gas being processed.

5. High-Temperature Dust-Laden Gas

When you deal with high-temperature dust-laden gas, you should apply insulation. This prevents moisture from condensing inside the collector. If the dust does not absorb moisture and the dew point is between 30°C and 50°C, you should set the collector temperature at least 30°C higher. If the dust is hygroscopic (such as cement, gypsum, or alkaline dust) and the dew point is between 20°C and 50°C, you should maintain the collector temperature 40°C to 50°C above the dew point.

6. Sealed Structure

You should ensure that the cyclone dust collector has a well-sealed structure to prevent any air leakage, especially during negative pressure operations. Additionally, you should emphasize the reliability of the discharge lock device.

7. Explosion-Proof Measures

 For flammable and explosive dust (such as coal dust), explosion-proof measures should be in place. A common practice is to install a safety explosion-proof valve in the inlet pipeline.

8. Dust Concentration Limits

When the dust is less viscous, you can relate the maximum allowable mass concentration of dust to the diameter of the cyclone. Specifically, a larger diameter allows for a higher allowable mass concentration.

WHAT ARE THE INSTALLATION POINTS? 

 

1.Ensure Uniform Airflow Distribution

 

When combining multiple cyclone dust collectors, it is essential to maintain uniform airflow to prevent short-circuiting. The inlet, hopper, and outlet zones must be properly sealed to avoid air leaks.

 

2.Material Selection

 

Depending on the operational conditions, cyclone dust collectors can be constructed from various materials, including steel, organic plastics, and ceramics. Selecting the right material is crucial for ensuring durability and resistance to wear and tear.

 

3.Positioning in Series

 

When connecting cyclone dust collectors in series, they should be arranged based on their performance. High-efficiency collectors should be placed first to capture the majority of the dust before it reaches lower-performing units.

HOW DO YOU MAINTAIN YOUR CYCLONE SEPARATOR?

I. Stable Operating Parameters

The operating parameters of a cyclone dust collector mainly include the inlet airflow velocity, the temperature of the gas being processed, and the inlet mass concentration of dust-laden gas.

♦Inlet Airflow Velocity

For a cyclone dust collector of fixed dimensions, increasing the inlet airflow velocity improves the gas handling capacity. It also effectively enhances separation efficiency. However, this increase also raises the pressure drop. Once the inlet airflow velocity reaches a certain value, the separation efficiency may decline. Additionally, wear may increase, and the lifespan of the cyclone dust collector may shorten. Therefore, you should maintain the inlet airflow velocity in the range of 18 to 23 m/s.

♦Temperature of the Processed Gas

As gas temperature increases, its viscosity rises, which increases the centripetal force acting on dust particles, leading to a decrease in separation efficiency. Therefore, cyclone dust collectors operating under high-temperature conditions should have a larger inlet airflow velocity and a smaller cross-sectional flow rate.

♦Inlet Mass Concentration of Dust-Laden Gas

A higher concentration of larger dust particles significantly carries smaller dust particles, which improves separation efficiency.

 

II. Preventing Air Leakage

 

Air leakage in a cyclone dust collector can severely impact dust removal efficiency. For instance, experts estimate that a 1% air leak at the lower cone or the discharge valve will decrease dust removal efficiency by 5%. Moreover, if a 5% leak occurs, the efficiency will drop by 30%. You can find air leakage in three areas. These areas are at the inlet and outlet flanges, in the body of the cyclone dust collector, and at the discharge mechanism.

 

The causes of air leakage include:

 

Flange Leakage: This is mainly caused by loose bolts, uneven gasket thickness, or irregular flange surfaces.

 

Body Leakage: The primary reason for leakage in the dust collector body is wear, particularly in the lower cone. Experience shows that when the mass concentration of dust-laden gas exceeds 10 g/m³, a 3 mm thick steel plate can wear out in less than 100 days.

 

Discharge Mechanism Leakage: This is mainly due to poor sealing in mechanical automatic discharge valves (e.g., weight-operated valves).

 

III. Preventing Wear in Key Areas

 

Factors affecting wear in critical areas include load, airflow velocity, and dust particle characteristics. The wear-prone areas include the casing, cone, and discharge outlet. Technical measures to prevent wear include:

 

Preventing Discharge Outlet Blockage: This mainly involves selecting high-quality discharge valves and regularly adjusting and maintaining them.

 

Preventing Excessive Gas Backflow into the Discharge Outlet: The discharge valves should be tightly sealed and properly weighted.

 

Regular Inspections: Frequent checks for air leaks due to wear should be conducted to take timely corrective measures.

 

Using Replaceable Wear Plates: In high-impact areas, install replaceable wear plates or increase the wear-resistant layer.

 

Minimizing Welds and Joints: Reduce the number of welds and joints; existing welds should be ground smooth, and flanges should have matching inner diameters and maintain good alignment.

 

Maintaining Airflow Velocities: The tangential velocity of airflow at the cyclone dust collector wall and the inlet airflow velocity should be kept within the critical range.

 

IV. Avoiding Dust Blockage and Buildup

 

Blockages and dust buildup in cyclone dust collectors mainly occur near the discharge outlet and in the intake and exhaust pipelines.

 

Discharge Outlet Blockage and Prevention Measures: Blockages at the discharge outlet are typically caused by two factors:

 

  • large materials or debris (such as shavings, wood chips, plastic bags, shredded paper, rags, etc.) getting stuck at the discharge outlet, leading to dust accumulation around them.
  • excessive dust accumulation in the hopper that has not been discharged in time. Preventive measures include adding a mesh at the intake and creating access holes above the discharge outlet (with covers and gaskets sealed with adhesive).

 

Intake and Exhaust Blockage and Prevention Measures: Improper design often causes blockages at the intake and exhaust ports. Rough right angles or slanted angles at the ports can lead to ash adhesion and buildup. This buildup eventually causes blockages.

CONCLUSION

Cyclone dust collectors are a vital component of effective dust management in industrial settings. By understanding the key design elements, adhering to installation best practices, and implementing innovations from Darko, operators can significantly enhance performance and efficiency. Regular maintenance and attention to detail will ensure that these systems operate at their best, providing a cleaner and safer working environment.

If you have any questions or would like to learn more about cyclone dust collectors and their applications, feel free to reach out.

October 7, 2024

Take a break and read all about it

Do You Want To Boost Your Business?

drop us a line and keep in touch