ダブルダンプバルブの仕組み[電気式と空圧式を解説】のページです。]

Introduction to Double Dump Valves

Double dump valves (also known as dual-flap valves または twin gate discharge valves) are essential components in powder and granular material handling systems. Widely used in cement plants, food processing, and metallurgy industries, these valves excel in:

✔ Make sure air doesn’t escape in pneumatic expressing systems.
✔ Ensuring continuous material flow control
✔ Providing airtight sealing for dust collection

1. Core Working Principle of Double Dump Valves

1.1 Basic Structure

Every double dump valve contains three critical components:

  • Upper and lower valve flaps (typically made of wear-resistant steel)

  • Heavy counterweight mechanism (for automatic flap reset)

  • Sealing gasket (usually food-grade rubber or PTFE)

1.2 Material Flow Process

The patented alternating flap system operates in 4 stages:

  1. Upper flap opens – Material enters the intermediate chamber

  2. Upper flap seals – Creates an airlock to prevent pressure loss

  3. Lower flap discharges – Material exits by gravity

  4. Lower flap resets – Counterweight ensures complete closure

Key Benefit: This sequential operation maintains constant system pressure while allowing uninterrupted material transfer – a critical advantage over rotary valves in high-pressure systems.

2. Electric Double Dump Valve Operation

2.1 Key Components

PartFunction
IP65-rated actuatorWeatherproof electric motor drive
Chain/belt transmissionConverts rotary to linear motion
Position sensorsProvides open/close feedback to PLC

2.2 Working Cycle

Opening Sequence:

① Motor energizes → ② Gearbox rotates shaft → ③ Upper flap opens (0-90°) → ④ Time delay (2-5 sec) → ⑤ Lower flap opens

Closing Sequence:

① Lower flap seals → ② Upper flap closes → ③ Limit switch signals completion

Pro Tip: Electric models achieve <0.5% leakage rates when paired with inflatable seals for abrasive materials like fly ash.

3. Pneumatic Double Dump Valve Mechanism

3.1 Air Cylinder Operation

  • Single-acting cylinders (spring return) for compact installations

  • Double-acting cylinders for high-speed cycling (up to 60 cycles/minute)

3.2 Critical Sealing Technology

について cone-and-spring sealing system provides:

  • Primary seal: Metal-to-metal contact between flap and seat

  • Secondary seal: Compressible elastomer gasket (FDA-approved options available)

Industry Application: Particularly effective in explosive environments (ATEX Zone 22) where electric sparks must be avoided.

ダブルデッカー・フラップ・ゲートバルブ

Comparative Analysis: Electric vs Pneumatic

特徴ElectricPneumatic
Response Time3-10 seconds<1 second
メンテナンスAnnual lubricationQuarterly diaphragm checks
エネルギー使用0.5-2 kW4-6 CFM @ 80 psi
Best ForPrecise positioningRapid cycling

Troubleshooting Common Issues

Problem 1: Material bridging

  • ソリューション:インストール vibrators または air cannons on valve body

Problem 2: Seal degradation

  • Diagnosis: Check for excessive play in linkage arms (>3mm indicates wear)

Problem 3: Incomplete closure

  • 修正: Adjust counterweight position or increase cylinder pressure by 10%

Industry-Specific Applications

✔ Cement Plants

  • Handles clinker dust at 300°C with water-cooled bearings

✔ Food Processing

  • 316 stainless steel models with sanitary clamps meet USDA standards

✔ Power Generation

  • Explosion-proof versions for coal fly ash collection

FAQs (Featured Snippet Optimization)

Q: How often should double dump valves be maintained?

A: Perform visual inspections weekly そして complete overhaul every 2,000 operating hours

A: Yes, when equipped with Teflon-coated flaps そして air purge connections

A: 5-7 years for standard models, 10+ years with hardened alloy components

Technical Specifications Table

ParameterRange
Sizes4″ to 24″ diameter
温度-40°F to 750°F
圧力Up to 15 PSI (standard)
材料Cast iron, SS304, SS316, AR steel

For double dump valve selection consultation or technical support, please contact  us.